This option avoids the requirement to ventilate the roof.
Epdm warm flat roof construction.
Consider geography budget and use for the roof to determine the best option.
Warm deck flat roofs can be constructed on most modern construction material types such as concrete timber and timber based sheets.
This type of roof construction has an insulation layer above the rafters and another layer immediately below its weather proof epdm membrane.
To use epdm for a warm deck flat roof construction solid closed cell roof insulation such as kingspan or celotex should be placed on top of the roof deck rather than in between the rafters.
Hot tar and gravel.
A waterproof layer which resists water.
The insulation material is placed immediately above the ceiling between the rafters.
From there the flat roof system you choose will determine the materials you apply.
This approach uses insulation with no air gap either immediately above or below the roof deck.
A cold deck is constructed as follows.
Epdm rubber warm roof being installed over old decking using a new vapour barrier and thermally broken fixings.
It consists of six basic elements.
Warm deck roof construction repair and replacement with an epdm rubber roofing membrane most new flat roof extensions are constructed using the warm roof method.
The benefits it provides and its cost effectiveness over a long term period have seen it become the flat roofing system of choice for many property owners.
A vapour control layer must be used below the insulation.
Flat roof construction flat roof construction diagram warm roof.
It helps to avoid condensation in the roof structure by ensuring the deck is maintained at a suitable temperature.
A note to consider before construction.
The guttering and gutter board has been remov.
Less thermally efficient than a warm roof construction cold roof construction remains the most common form of construction for existing flat roofs.
The 3 most common materials used for flat roof construction.
Thermal insulation which retains heat within the building rather than allowing it to escape through the roof.
If insulation is installed below the flat roof deck this is called a cold roof.
Epdm rubber roofing has firmly established itself as one of the most popular options for flat roofing of all sizes.
A 50mm air gap must be left.
A vapour barrier to prevent moisture.
There are several methods and materials for the design of the exterior surface of a warm or cold flat roof.
This is where the insulation is typically packed between the rafters.