Insulation cover boards training and education take advantage of industry leading training and education though care the center for the advancement of roofing excellence.
Flat roof insulation screws.
Extra high load fasteners are 21 fasteners with a 3 phillips head.
These sturdy screws and plates may be used in both residential and commercial settings.
Mechanically fastened roofs attach primarily with screws and metal plates rather than glue.
Insulation screws with plates 100 pack are recommended for use in fastening rigid insulation to your roof deck.
Single ply roofing is either fully adhered or mechanically attached.
This gentite 4 in.
Finishes are all high performance polymers or stainless steel screws are available.
We are there when you need us so give us a call today.
Flat roof insulation installation the rigid foam board insulation we used was 2 thick and came in 4 x 8 sheets.
A fibertite mechanically attached roofing system uses flat roof insulation fasteners and stress plates that are designed and engineered to secure the insulation and cover boards to steel wood and concrete roof decks.
Also known as roofing screws these screws are long and made from hardened steel to fasten rigid insulation board to steel decking.
Hammer in non threaded fasteners designed to secure insulation and single ply membrane to structural concrete.
Made from steel they re coated to resist corrosion in wet environments.
Larger plates 2 3 4 to 3 are for insulation board.
The fully adhered method consists of gluing the membrane directly to insulation or to the substrate.
They save you time and effort by drilling their own holes and fastening in a single operation.
Roof stress plate design.
Smaller plates 2 to 2 1 2 inches are for membrane and seams.
Plates are design to fit the roofing screw wire size 12 14 15 or 21 gauge and the head design truss phillips head and hex washer head.
Omg supplies roofing fasteners for the roofing industry as well as pipe supports insulation adhesives retrofit roof drains and construction accessories.
Extra high load fasteners are only compatible with extra high load plates.
The mechanically attached method consists of fastening each row of membrane to the roof deck with screws and barbed plates.
Fasteners are typically spaced 12 inches o c.
Length is measured from under the head.
Once the roof demo was complete and the flat roof was cleared of any remaining debris some rotted 2x material around the perimeter of the roof was replaced.
Polymer gyptec glass filled nylon auger fastener with a 1 in.