If the allowed vent feet are exceeded then you will have trouble with the pressure switch not staying closed.
Furnace pressure switch stuck closed.
The leakage based on location could be a failed gasket or even the drain line connection.
Tapping lightly on the pressure switch body may open the switch and the unit may start.
Pressure switch fails closed normally this would indicate a failed pressure switch the furnace will test to make sure the switch is open before starting the ventor motor.
Which is why i made this video that go.
If the inducer comes on the pressure switch is stuck closed.
It needs to be open until the draft inducer comes on.
When it thows a stuck pressure switch error you should check the voltage drop across it or disconnect it and ohm out.
If it s truly stuck closed you need to replace the pressure switch.
The plunger may not be pulling in completely and may only bob around when the pressure builds up inside the furnace.
The source of pressure switch problems can sometimes be a pain to track down.
If you have exceeded the number of turns the furnace will not run right and the pressure switch will not work or stay closed.
The pressure switch must be replaced.
The 90 degree turns in the venting sometimes are calculated as 5 feet of piping.
Using a cloth and a wire brush remove any blockages and dirt from the secondary exchanger and the inducer.
Pressure switch stuck closed.
If your pressure switch is stuck it is most likely a problem in the running of the furnace.
Nordyne furnace error code.
Furnace pressure switch troubleshooting.
If you get a pressure switch code and the inducer will not come on remove one of the wires from the pressure switch.